Enviar a
FL
0
  • argentina
  • chile
  • colombia
  • españa
  • méxico
  • perú
  • estados unidos
  • internacional

Selecciona tu país

América

Europa

Resto del mundo

portada Loss of Start-Up Oxygen in CSE SR-100 Self-Contained Self-Rescuers (en Inglés)
Formato
Libro Físico
Editorial
Idioma
Inglés
N° páginas
26
Encuadernación
Tapa Blanda
Dimensiones
28.0 x 21.6 x 0.1 cm
Peso
0.09 kg.
ISBN13
9781493554461

Loss of Start-Up Oxygen in CSE SR-100 Self-Contained Self-Rescuers (en Inglés)

Centers for Disease Cont And Prevention (Autor) · National Institute Fo Safety and Health (Autor) · D. Human Services (Autor) · Createspace · Tapa Blanda

Loss of Start-Up Oxygen in CSE SR-100 Self-Contained Self-Rescuers (en Inglés) - And Prevention, Centers for Disease Cont ; Safety and Health, National Institute Fo ; Human Services, D.

Libro Nuevo Origen: Estados Unidos
Envío: 7 a 9 días háb.
$ 11.99$ 10.58
-12%
Libro Nuevo

Quedan más de 100 unidades

$ 10.58
Llega entre el 28 Jul y el 03 Ago a FL. Seleccionar ubicación

Reseña del libro "Loss of Start-Up Oxygen in CSE SR-100 Self-Contained Self-Rescuers (en Inglés)"

This report describes a National Institute for Occupational Safety and Health (NIOSH) and Mine Safety and Health Administration (MSHA) investigation assessing the prevalence of a lack of sufficient start-up oxygen in CSE SR-100 self-contained self-rescuer (SCSR) devices. The availability of sufficient start-up oxygen is critical to the performance of the SR-100. As part of a routine field testing program of SCSRs used in coal mines, NIOSH and MSHA detected two SR-100s that lacked sufficient start-up oxygen. CSE Corporation subsequently discovered one SCSR that lacked sufficient start-up oxygen in that company's internal quality control program and voluntarily stopped further production and sales of SR-100s. NIOSH developed a protocol to test for the presence of start-up oxygen in field-deployed SR100s. The purpose of the test was to determine if the failure rate of the start-up oxygen in the population of 70,000 field-deployed units exceeded 1%. NIOSH and MSHA used American Society for Quality (ASQ), Sampling Procedures and Tables for Inspection of Isolated Lots by Attributes (ASQC Q3-1988). In assessing the SR-100s, if no more than 3 failures of start-up oxygen occurred in the 500-unit random sample, the SR-100 could be accepted as meeting the Limiting Quality (LQ) rate of 1.25% for start-up oxygen performance.

Opiniones del libro

Preguntas frecuentes sobre el libro

Todos los libros de nuestro catálogo son Originales.
El libro está escrito en Inglés.
La encuadernación de esta edición es Tapa Blanda.

Preguntas y respuestas sobre el libro

¿Tienes una pregunta sobre el libro? Inicia sesión para poder agregar tu propia pregunta.

Opiniones sobre Buscalibre

Ver más opiniones de clientes