Hasta 50% off y Envío a todo USA y PR por solo $2.99   Ver más

Enviar a
FL
0
es
  • argentina
  • chile
  • colombia
  • españa
  • méxico
  • perú
  • estados unidos
  • internacional

Selecciona tu país

América

Europa

Resto del mundo

Idioma
esEspañolActual
enEnglish
portada Junction-To-Case Thermal Resistance of a Silicon Carbide Bipolar Junction Transistor Measured (en Inglés)
Formato
Libro Físico
Editorial
Idioma
Inglés
N° páginas
22
Encuadernación
Tapa Blanda
Dimensiones
9.69x7.44x0.04 in
Peso
0.06 kg.
ISBN13
9781287235521

Junction-To-Case Thermal Resistance of a Silicon Carbide Bipolar Junction Transistor Measured (en Inglés)

Nasa Technical Reports Server (Ntrs) (Autor) · Janis M. Niedra (Autor) · Bibliogov · Tapa Blanda

Junction-To-Case Thermal Resistance of a Silicon Carbide Bipolar Junction Transistor Measured (en Inglés) - Niedra, Janis M. ; Nasa Technical Reports Server (Ntrs)

Más barato Libro Nuevo Origen: Estados Unidos
Envío: 10 a 12 días háb.
$ 14.75$ 13.88
-6%
Más rápido Libro Nuevo Origen: Estados Unidos
Envío: 7 a 9 días háb.
$ 20.38$ 19.18
-6%
Libro Nuevo Más barato

Quedan más de 100 unidades

$ 13.88
Llega entre el 24 Nov y el 01 Dic a FL. Seleccionar ubicación

Reseña del libro "Junction-To-Case Thermal Resistance of a Silicon Carbide Bipolar Junction Transistor Measured (en Inglés)"

Junction temperature of a prototype SiC-based bipolar junction transistor (BJT) was estimated by using the base-emitter voltage (V(sub BE)) characteristic for thermometry. The V(sub BE) was measured as a function of the base current (I(sub B)) at selected temperatures (T), all at a fixed collector current (I(sub C)) and under very low duty cycle pulse conditions. Under such conditions, the average temperature of the chip was taken to be the same as that of the temperature-controlled case. At increased duty cycle such as to substantially heat the chip, but same I(sub C) pulse height, the chip temperature was identified by matching the V(sub BE) to the thermometry curves. From the measured average power, the chip-to-case thermal resistance could be estimated, giving a reasonable value. A tentative explanation for an observed bunching with increasing temperature of the calibration curves may relate to an increasing dopant atom ionization. A first-cut analysis, however, does not support this.

Opiniones del libro

Preguntas frecuentes sobre el libro

Todos los libros de nuestro catálogo son Originales.
El libro está escrito en Inglés.
La encuadernación de esta edición es Tapa Blanda.

Preguntas y respuestas sobre el libro

¿Tienes una pregunta sobre el libro? Inicia sesión para poder agregar tu propia pregunta.

Opiniones sobre Buscalibre

Ver más opiniones de clientes